Apart from removing a listed component, a repair counts as major if it uncovers an opening of more than how…

Recovery requirements · EPA 608 Type II. The correct answer, and the reasoning behind it.

Evacuation levels by charge size and equipment date, major repairs, and system-dependent limits.

The question

Apart from removing a listed component, a repair counts as major if it uncovers an opening of more than how much flow area, for how long?

  • 2 square inches for more than 30 minutes
  • 4 square inches for more than 15 minutesCorrect answer
  • 4 square inches for more than 60 minutes
  • 8 square inches for more than 15 minutes

Why “4 square inches for more than 15 minutes” is correct

The definition covers any repair that uncovers more than 4 square inches of flow area for more than 15 minutes. That much open area for that long lets in enough air and moisture to treat the job like a component replacement.

Source: 40 CFR 82.152

Why the other answers are wrong

  • 2 square inches for more than 30 minutes — Both numbers are wrong; the rule is 4 square inches and 15 minutes.
  • 4 square inches for more than 60 minutes — The time limit is 15 minutes, not an hour.
  • 8 square inches for more than 15 minutes — The area limit is 4 square inches, not 8.

Practice more of this

More EPA 608 Type II practice questions, or see every EPA 608 practice test.

Unofficial, not affiliated with the EPA or any EPA-approved certifying organization. Questions are original practice written from public EPA material, not real exam questions.