Using recovery equipment made in 2016, how much must be recovered at minimum?

Recovery requirements · EPA 608 Type I. The correct answer, and the reasoning behind it.

The small-appliance definition and the recovery levels required.

The question

A chest freezer holds 1.5 pounds of refrigerant and its compressor will not run. Using recovery equipment made in 2016, how much must be recovered at minimum?

  • 1.35 pounds
  • 1.2 poundsCorrect answer
  • 1.5 pounds
  • 1.05 pounds

Why “1.2 pounds” is correct

With equipment made on or after November 15, 1993 and a compressor that is not functioning, the level is 80 percent, and 80 percent of 1.5 pounds is 1.2 pounds. The 4-inch vacuum option is also available.

Source: 40 CFR 82.156(b)

Why the other answers are wrong

  • 1.35 pounds — That is 90 percent, which applies only when the compressor is functioning.
  • 1.5 pounds — The rule does not require the full charge.
  • 1.05 pounds — That is only 70 percent, below the required level.

Practice more of this

More EPA 608 Type I practice questions, or see every EPA 608 practice test.

Unofficial, not affiliated with the EPA or any EPA-approved certifying organization. Questions are original practice written from public EPA material, not real exam questions.