Can she combine them into Universal certification?
Recovery requirements · EPA 608 Type I. The correct answer, and the reasoning behind it.
The small-appliance definition and the recovery levels required.
The question
A technician passed a mail-in Type I test, then passed proctored Core, Type II and Type III tests. Can she combine them into Universal certification?
- Yes, passing scores on separate tests always combine
- Yes, if her mail-in score was 84 percent or higher
- Yes, if she retakes the Core section only
- No; Type I must be passed closed-book and proctoredCorrect answer
Why “No; Type I must be passed closed-book and proctored” is correct
Appendix D states that mail-in format Type I tests cannot be used toward a Universal certification. Universal requires closed-book, proctored testing, and the Type I portion taken as part of Universal is closed-book.
Source: 40 CFR Part 82 Subpart F, Appendix D
Why the other answers are wrong
- Yes, passing scores on separate tests always combine — Separate tests combine only when each was taken in a form allowed for Universal.
- Yes, if her mail-in score was 84 percent or higher — Even a passing mail-in score cannot be used toward Universal.
- Yes, if she retakes the Core section only — The problem is the mail-in Type I, not the Core section.
Practice more of this
More EPA 608 Type I practice questions, or see every EPA 608 practice test.
Unofficial, not affiliated with the EPA or any EPA-approved certifying organization. Questions are original practice written from public EPA material, not real exam questions.