What is the highest pressure the leaking component may be at when it is opened?
Recovery requirements · EPA 608 Type II. The correct answer, and the reasoning behind it.
Evacuation levels by charge size and equipment date, major repairs, and system-dependent limits.
The question
Leaks in an R-22 appliance make it impossible to reach the Table 1 level. What is the highest pressure the leaking component may be at when it is opened?
- 5 psig
- 0 psigCorrect answer
- 10 inches of Hg vacuum
- 15 psig
Why “0 psig” is correct
When leaks make Table 1 levels unattainable, the leaking component must be evacuated to the lowest level that can be reached without substantially contaminating the refrigerant. That level may not exceed 0 psig.
Source: 40 CFR 82.156(a)(2); EPA: Service Practice Requirements
Why the other answers are wrong
- 5 psig — 5 psig is the limit for oil changes, not for leaking components.
- 10 inches of Hg vacuum — 10 inches is a Table 1 level, which the leaking component cannot reach in this case.
- 15 psig — No rule lets a leaking component be opened above 0 psig.
Practice more of this
More EPA 608 Type II practice questions, or see every EPA 608 practice test.
Unofficial, not affiliated with the EPA or any EPA-approved certifying organization. Questions are original practice written from public EPA material, not real exam questions.