After installing a piercing access valve on a refrigerator's process stub, what should the technician check…

Recovery techniques · EPA 608 Type I. The correct answer, and the reasoning behind it.

Identifying refrigerants, access valves, passive recovery and solderless fittings.

The question

After installing a piercing access valve on a refrigerator's process stub, what should the technician check before starting a vacuum-assisted recovery?

  • That the appliance has been charged with extra refrigerant
  • That the thermostat is set to its coldest setting
  • That the valve seals tightly, so no air is drawn inCorrect answer
  • That the process stub has been cut open

Why “That the valve seals tightly, so no air is drawn in” is correct

A loose piercing valve can leak refrigerant out or, under vacuum, pull air in. Air in the recovered refrigerant is a noncondensable contaminant, so the fitting should be sealed and leak-free before recovery starts.

Source: EPA: Test Topics

Why the other answers are wrong

  • That the appliance has been charged with extra refrigerant — Adding refrigerant before recovery makes no sense.
  • That the thermostat is set to its coldest setting — The thermostat setting does not affect the seal of the fitting.
  • That the process stub has been cut open — Cutting the stub would release refrigerant; the piercing valve makes the opening.