After installing a piercing access valve on a refrigerator's process stub, what should the technician check…
Recovery techniques · EPA 608 Type I. The correct answer, and the reasoning behind it.
Identifying refrigerants, access valves, passive recovery and solderless fittings.
The question
After installing a piercing access valve on a refrigerator's process stub, what should the technician check before starting a vacuum-assisted recovery?
- That the appliance has been charged with extra refrigerant
- That the thermostat is set to its coldest setting
- That the valve seals tightly, so no air is drawn inCorrect answer
- That the process stub has been cut open
Why “That the valve seals tightly, so no air is drawn in” is correct
A loose piercing valve can leak refrigerant out or, under vacuum, pull air in. Air in the recovered refrigerant is a noncondensable contaminant, so the fitting should be sealed and leak-free before recovery starts.
Source: EPA: Test Topics
Why the other answers are wrong
- That the appliance has been charged with extra refrigerant — Adding refrigerant before recovery makes no sense.
- That the thermostat is set to its coldest setting — The thermostat setting does not affect the seal of the fitting.
- That the process stub has been cut open — Cutting the stub would release refrigerant; the piercing valve makes the opening.