Where should access valves be installed?

Recovery techniques · EPA 608 Type I. The correct answer, and the reasoning behind it.

Identifying refrigerants, access valves, passive recovery and solderless fittings.

The question

A refrigerator's compressor will not run, and the technician is recovering with a passive device. Where should access valves be installed?

  • On the low side only
  • On both the high side and the low sideCorrect answer
  • On the high side only
  • Through a hole drilled in the compressor shell

Why “On both the high side and the low side” is correct

EPA's test topics stress installing both high- and low-side access valves when the compressor is inoperative. Without a running compressor to move it, refrigerant must be drawn from both sides of the system.

Source: EPA: Test Topics

Why the other answers are wrong

  • On the low side only — With the compressor stopped, refrigerant on the high side may stay trapped.
  • On the high side only — Refrigerant on the low side may stay trapped if only the high side is tapped.
  • Through a hole drilled in the compressor shell — Access is made on the tubing, typically the process stub and a high-side line, not through the shell.

Practice more of this

More EPA 608 Type I practice questions, or see every EPA 608 practice test.